iJen MOVING series – Sanitizing surfaces and environments with UVC

Sanitizer for vehicles and small environments with germicidal ultraviolet radiation, in the presence of ozone

The iJen MOVING series has been designed to meet the need for sanitizing small environments such as car cabins, closets, changing rooms, medical offices, beauty treatment rooms, hotel rooms.

IJen MOVING products are portable and easy to handle, therefore they can be easily moved from one room to another, allowing the sanitization in a few minutes, for example, of rooms with cubic capacity up to 75 cubic meters.

The iJen MOVING series is available in 4 models:

  • MOVING Case 
    Suitcase system for vehicle sanitization (powered at 12Vdc)
  • MOVING Box12 e Box24 
    Portable system with two lamps suitable for even large vehicles (powered at 12Vdc or 24Vdc)
  • MOVING Box220 
    Portable system with two lamps suitable for large vehicles, small environments, such as changing rooms, closets, medical offices, beauty treatment rooms (powered at 12Vdc or 220Vac)
  • MOVING Room 
    Portable floor stand system, with four lamps, suitable for small / medium rooms such as medical offices, beauty treatment rooms, hotel rooms (powered at 220Vac)

The effectiveness of the germicidal action of the iJen MOVING series products depends on many factors:

  • The power variations of the UVC source: the lamps used in the iJen MOVING series have been sized in such a way as to guarantee an excellent level of sanitation in environments up to 40-75 cubic meters.
  • The amount of exposure time: the table below provides some examples of the minimum recommended exposure times to UVC light (with ozone), calculated based on the volume of the environment to be sanitized and the characteristics of the UVC source used in iJen MOVING
Exposure time Volume (min-max)
 iJen MOVING Case 2 mc (*) 4 mc (*)
10 min 15 min

 

Exposure time Volume (min-max)
  4 mc (*) 12 mc (*) 25 mc (*) 50 mc (*)
iJen MOVING Box12 8 min 12 min
iJen MOVING Box220 8 min 12 min 15 min 20 min

 

Exposure time Volume (min-max)
 iJen MOVING Room 25 mc (*) 50 mc (*) 75 mc (*)
8 min 12 min 18 min

Note

(*) the volume of the room is calculated assuming the space free from obstacles

Frequent sanitization reduces the treatment time, increasing its effectiveness.
The presence of particles (such as dust) can decrease the germicidal efficacy of UV light on microorganisms. It is therefore recommended to use iJen MOVING in clean environments.

iJen MOVING series – Datasheet

iJen MOVING Series – Brochure

iJen MOVING Case

The iJen MOVING Case product is used to sanitize the interior of vehicles. Handy and light, it is very easy to use and suitable for cubes up to 4 cubic meters.

iJen MOVING Case uses the vehicle’s 12Vdc power supply, and is equipped with a 15W UVC lamp, which emits germicidal radiation at 254nm and optionally at 185nm (for the production of ozone, useful for the abatement of bad smells).

The position and inclination of the lamp is adjustable thanks to the adjustable support.

The switching on of the lamp and the duration of the UVC exposure time are regulated by a configurable timer by acting on the joystick on board or by using the Finder Tool Box NFC app.

For a correct use it is recommended to:

  • Adjust the timer for switching on the lamp to a value of about 20 seconds: this allows you to exit the vehicle and close the doors before the UVC lamp begins to radiate into the environment.
  • Adjust the exposure time based on the volume of the passenger compartment to be sanitized, as indicated in the “exposure times” table.
  • Turn off the air conditioner and start the air recirculation function while using the iJen MOVING Case.
  • When the is lamp turned off, the interior of the vehicle is sanitized. Before using the vehicle, turn off the air recirculation and leave the fan on, even with air conditioning, for about 1 minute.

 

The laminated glass used for the windshield, rear window and windows of vehicles, thanks to the additional layer of PVB, is able to reject up to 99% of UV rays, therefore also UVC wavelengths. This allows you to stop near the vehicle without running any danger.

Do not expose yourself and animals directly to UVC light as it is harmful to humans and other forms of life (prolonged exposure can cause temporary damage such as dermatitis or conjunctivitis or very serious damage such as tumors or blindness).


iJen MOVING Box12 e Box24

The iJen MOVING Box12 and Box24 products are used to sanitize the interior of even large vehicles (vans, campers ..). They are suitable for cubes up to 25mc and are powered respectively by the 12Vdc or 24Vdc socket of the vehicle.

They are equipped with 1 or 2 15W UVC lamps, which emit germicidal radiations at 254nm and optionally at 185nm (for the production of ozone, useful for the abatement of bad smells).

The use of 2 lamps allows you to irradiate a larger surface without increasing exposure times. The position and inclination of the lamps is adjustable thanks to the adjustable support.

The switching on of the lamp and the duration of the UVC exposure time are regulated by a configurable timer by acting on the joystick on board or by using the Finder Tool Box NFC app.

For a correct use it is recommended to:

  • Adjust the timer for switching on the lamp to a value of about 20 seconds: this allows you to exit the vehicle and close the doors before the UVC lamp begins to radiate into the environment.
  • Adjust the exposure time based on the volume of the passenger compartment to be sanitized, as indicated in the “exposure times” table.
  • Turn off the air conditioner and start the air recirculation function while using the iJen MOVING Box12 o Box24.
  • When the lamps are turned off, the interior of the vehicle is sanitized. Before using the vehicle, turn off the air recirculation and leave the fan on, even with air conditioning, for about 1 minute.

 

The laminated glass used for the windshield, rear window and windows of vehicles, thanks to the additional layer of PVB, is able to reject up to 99% of UV rays, therefore also UVC wavelengths. This allows you to stop near the vehicle without running any danger.

Do not expose yourself and animals directly to UVC light as it is harmful to humans and other forms of life (prolonged exposure can cause temporary damage such as dermatitis or conjunctivitis or very serious damage such as tumors or blindness).


iJen MOVING Box220

The iJen MOVING Box220 product is used to sanitize small areas such as the interior of large cars (vans, campers), small rooms such as changing rooms, closets, medical offices, beauty treatment rooms.

It is suitable for cubes up to 25 mc and can be powered via the vehicle’s 12Vdc socket or via the 220Vac mains voltage.

 

They are equipped with 2 15W UVC lamps, which emit germicidal radiations at 254nm and optionally at 185nm (for the production of ozone, useful for the abatement of bad smells).

The use of 2 lamps allows you to irradiate a larger surface without increasing exposure times. The position and inclination of the lamps is adjustable thanks to the adjustable support.

iJen MOVING Box220 is equipped with a presence sensor that allows you to turn off the lamps if a person or an animal approaches the system when the lamps are in operation (min distance 5 meters)

The switching on of the lamp and the duration of the UVC exposure time are regulated by a configurable timer by acting on the joystick on board or by using the Finder Tool Box NFC app.

For a correct use it is recommended to:

  • In the case of using the iJen MOVING Box220 to sanitize a vehicle, adjust the timer for switching on the lamp for a value of about 20 sec: this allows you to exit the vehicle and close the doors before the UVC lamp starts to irradiate in the environment.
  • If the iJen MOVING Box220 is used to sanitize a room, adjust the timer for switching on the lamp for a value of about 30 sec: this allows you to leave the room and close the doors before the UVC lamp starts to irradiate in the environment.
  • Adjust the exposure time based on the volume of the passenger compartment to be sanitized, as indicated in the “exposure times” table.
  • In the case of using the iJen MOVING Box220 to sanitize a vehicle, turn off the air conditioner and start the air recirculation.
  • When the lamps are turned off, the environment is sanitized. Before staying there, if necessary, disable the air circulation and ventilate the room for about 1 minute.

 

The laminated glass used for the windshield, rear window and windows of vehicles, thanks to the additional layer of PVB, is able to reject up to 99% of UV rays, therefore also UVC wavelengths. This allows you to stop near the vehicle without running any danger.

Do not expose yourself and animals directly to UVC light as it is harmful to humans and other forms of life (prolonged exposure can cause temporary damage such as dermatitis or conjunctivitis or very serious damage such as tumors or blindness).


iJen MOVING Room

The iJen MOVING Room product is a portable, free-standing system with four lamps suitable for small / medium rooms such as doctors’ offices, beauty treatment rooms, hotel rooms.

It is suitable for cubes up to 75mc and is powered by the 220V AC mains voltage and is equipped with 55W UVC lamps, which emit germicidal radiation at 254nm and optionally at 185nm (for the production of ozone, useful for the abatement of bad smells).

iJen MOVING Room is equipped with a presence sensor that allows you to turn off the lamps if a person or an animal approaches the system when the lamps are in operation (min distance 5 meters)

The switching on of the lamp and the duration of the UVC exposure time are regulated by a configurable timer by acting on the joystick on board or by using the Finder Tool Box NFC app.

For a correct use it is recommended to:

  • Adjust the timer for switching on the lamp for a value of about 30 sec: this allows you to leave the room and close the doors before the UVC lamp starts to irradiate in the environment.
  • Adjust the exposure time based on the volume of the passenger compartment to be sanitized, as indicated in the “exposure times” table.
  • Turn off any air conditioning system while using the iJen MOVING Room.
  • When the lamps are turned off, the interior of the room is sanitized. Ventilate the room and wait approximately 2-3 minutes before staying there.

Do not expose yourself and animals directly to UVC light as it is harmful to humans and other forms of life (prolonged exposure can cause temporary damage such as dermatitis or conjunctivitis or very serious damage such as tumors or blindness).